ASTM D5470 standard 300℃ Thermal Thermal Conductivity Testing Machine

  • 1
  • 2
  • 3

Brand Name : DAXIAN

Model Number : DX8377A

Certification : ASTM D5470

Place of Origin : China

MOQ : 1 set

Price : Negotiable

Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash

Supply Ability : 30 sets per month

Delivery Time : 15 work days after order confirmed

Packaging Details : Wooden case

Name : ASTM D5470 standard 300℃ Thermal Thermal Conductivity Testing Machine

Temperature : 300℃

Accuracy : 5%

Power supply : AC 220V; 50HZ

Standard : ASTM D5470

Heat flow range : 0.5-2000W/m2

The timing part range : 0 ~ 999.9s; resolution 0.1s;

Warranty : 12 months

Contact Now

ASTM D5470 standard 300℃ Thermal Thermal Conductivity Testing Machine

Scope of application:

Thermal conductivity of dry test pieces of clay and sand, the thermal resistance of the sample should be greater than 0.1m2.K / W.

A thermal flow meter is used to detect the thermal conductivity and thermal resistance of clay, sand, etc., and the computer is used to realize automatic detection and generate an experimental report. The instrument adopts a stable hot surface temperature on the side of the sample, and the heat is transferred to the cold surface (room temperature) through the sample, and the transferred heat flow is measured to calculate the thermal conductivity and thermal resistance. Specially equipped with geotechnical sample cylinder and specific heat capacity test device, which can be used for thermal conductivity analysis and specific heat capacity determination of clay, sand and other soils.

Standard:

ASTM D5470-12 (Test Standard for Heat Transfer Properties of Thin ThermalConductive Solid Electrical insulation Materials), etc.

Technical parameters:

1. Thermal conductivity range:

Plate-like sample 0.015-400W/mk, accuracy better than 5%; Cylindrical sample 3-400W/mk, accuracy less than 5%;

(A round sample cylinder with rock-finish soil, Ф90mm)

2. Hot surface temperature: room temperature -99.99 °C, the use of high digital display meter temperature measurement, 0.2 precision, resolution 0.01 °C.

3. Cold surface temperature: room temperature, using a high digital display meter temperature measurement, 0.2 accuracy, resolution 0.01 °C.

4. Hot surface temperature control: room temperature -99.99 °C, using a high number of digital display meter temperature measurement, 0.2 accuracy, resolution 0.01 °C, flat heater, two-way SCR control.

5. Cold forced air cooling. The cold side is water-cooled to ensure stable cold face temperature (optional for temperature users)

6. Using computer automatic testing.

7. Heat flow range: 0.5-2000W/m2, delivery rate of 0.25 W/m2.

8. Using WPY heat flow meter, heat flow parameters 23.26w/m2.mV.

9. Using plexiglass windshield, can directly observe the experimental process.

10. Uot and cold plate heat transfer area: 150 × 150 (mm), (can be manufactured according to user requirements 300/300,600/600 and other specifications of the sample).

11. Adjustable hot and cold plate spacing: 0-160 (mm).

The main technical parameters:

The test range 0.1 ~ 300w/m • k
Power supply AC 220V; 50HZ
Heat source heating copper block, using 36V safe voltage heating.
Test materials block or cylindrical metal, non-metallic materials, can test powder, gelatinous and other samples;
Measuring temperature range room temperature ~ 250 °C, up to 550 °C, accuracy ± 1 °C;
The timing part range 0 ~ 999.9s; resolution 0.1s;
Thermal conductivity measurement accuracy better than 10%
Sample size Φ130 × (1-100) mm

ASTM D5470 standard 300℃ Thermal Thermal Conductivity Testing Machine

FAQ

Q:Are you factory or trading company?

A:We are factory in Dongguan City, Guangdong Province,China.Near Shenzhen or Guangzhou.

Q:What kind of certificate you have?

A:ISO9001 Certification, CE Certification.

Q:What is the lead time of the product?

A: Generally 7-15 days after getting the deposit.

Q:How about the payment term?

A: T/T, by cash, western union, or L/C.

Q:How about the warranty term?

A:1 year warranty,The engineer can teach the machine on the spot.


Product Tags:

ASTM D5470 thermal conductivity tester

      

300℃ thermal testing machine

      

lab thermal conductivity analyzer

      
Quality ASTM D5470 standard 300℃ Thermal Thermal Conductivity Testing Machine for sale

ASTM D5470 standard 300℃ Thermal Thermal Conductivity Testing Machine Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)